Finite-Element Performance Evaluation of On-Line Transformer Internal Fault Detection Based on Instantaneous Voltage and Current Measurements

This paper investigates the performance of a recently proposed online transformer internal fault detection technique through detailed non-linear three-dimensional finite element modelling of the windings, magnetic core and transformer tank. The online technique considers correlation of transformer i...

Full description

Bibliographic Details
Main Authors: Masoum, A., Hashemnia, Naser, Abu Siada, Ahmed, Masoum, Mohammad, Islam, S.
Format: Journal Article
Published: Engineers Australia 2013
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/14645
_version_ 1848748678581321728
author Masoum, A.
Hashemnia, Naser
Abu Siada, Ahmed
Masoum, Mohammad
Islam, S.
author_facet Masoum, A.
Hashemnia, Naser
Abu Siada, Ahmed
Masoum, Mohammad
Islam, S.
author_sort Masoum, A.
building Curtin Institutional Repository
collection Online Access
description This paper investigates the performance of a recently proposed online transformer internal fault detection technique through detailed non-linear three-dimensional finite element modelling of the windings, magnetic core and transformer tank. The online technique considers correlation of transformer instantaneous input and output voltage difference and input current at the power frequency and uses the ellipse shape ΔV-I locus as the finger print of the transformer that could be measured every cycle to identify any incipient faults. The technique is simple, fast and suitable for online monitoring of in-service transformers. A detailed three-dimensional finite element model of single-phase transformer is developed and various physical winding deformations with different fault levels are simulated to assess their impacts on the online ΔV-I locus. As transformer field testing under various internal fault conditions cannot be easily conducted, the main contributions of this paper are accurate finite element based implementation, testing and performance evaluation of the online fault detection approach. Furthermore, the impact of winding short circuit fault on the ΔV-I locus has been also measured and validated.
first_indexed 2025-11-14T07:08:52Z
format Journal Article
id curtin-20.500.11937-14645
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:08:52Z
publishDate 2013
publisher Engineers Australia
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-146452017-09-13T14:07:13Z Finite-Element Performance Evaluation of On-Line Transformer Internal Fault Detection Based on Instantaneous Voltage and Current Measurements Masoum, A. Hashemnia, Naser Abu Siada, Ahmed Masoum, Mohammad Islam, S. power transformer On-line condition monitoring frequency response analysis and finite-element This paper investigates the performance of a recently proposed online transformer internal fault detection technique through detailed non-linear three-dimensional finite element modelling of the windings, magnetic core and transformer tank. The online technique considers correlation of transformer instantaneous input and output voltage difference and input current at the power frequency and uses the ellipse shape ΔV-I locus as the finger print of the transformer that could be measured every cycle to identify any incipient faults. The technique is simple, fast and suitable for online monitoring of in-service transformers. A detailed three-dimensional finite element model of single-phase transformer is developed and various physical winding deformations with different fault levels are simulated to assess their impacts on the online ΔV-I locus. As transformer field testing under various internal fault conditions cannot be easily conducted, the main contributions of this paper are accurate finite element based implementation, testing and performance evaluation of the online fault detection approach. Furthermore, the impact of winding short circuit fault on the ΔV-I locus has been also measured and validated. 2013 Journal Article http://hdl.handle.net/20.500.11937/14645 10.7158/E13-190.2014.11.4 Engineers Australia restricted
spellingShingle power transformer
On-line condition monitoring
frequency response analysis and finite-element
Masoum, A.
Hashemnia, Naser
Abu Siada, Ahmed
Masoum, Mohammad
Islam, S.
Finite-Element Performance Evaluation of On-Line Transformer Internal Fault Detection Based on Instantaneous Voltage and Current Measurements
title Finite-Element Performance Evaluation of On-Line Transformer Internal Fault Detection Based on Instantaneous Voltage and Current Measurements
title_full Finite-Element Performance Evaluation of On-Line Transformer Internal Fault Detection Based on Instantaneous Voltage and Current Measurements
title_fullStr Finite-Element Performance Evaluation of On-Line Transformer Internal Fault Detection Based on Instantaneous Voltage and Current Measurements
title_full_unstemmed Finite-Element Performance Evaluation of On-Line Transformer Internal Fault Detection Based on Instantaneous Voltage and Current Measurements
title_short Finite-Element Performance Evaluation of On-Line Transformer Internal Fault Detection Based on Instantaneous Voltage and Current Measurements
title_sort finite-element performance evaluation of on-line transformer internal fault detection based on instantaneous voltage and current measurements
topic power transformer
On-line condition monitoring
frequency response analysis and finite-element
url http://hdl.handle.net/20.500.11937/14645