Development of an Online Automatic Diagnostic Reference Levels Management System for Digital Radiography: A Pilot Experience

The diagnostic reference levels (DRLs) concept is a methodology proposed by the International Commission on Radiological Protection (ICRP) for identifying any unusual high patient doses involved in radiological examinations. However, some challenges are anticipated in the DRLs concept including reso...

Full description

Bibliographic Details
Main Authors: Ng, Curtise, Sun, Zhonghua
Format: Journal Article
Published: Elsevier Ireland Ltd 2011
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/14141
_version_ 1848748542118592512
author Ng, Curtise
Sun, Zhonghua
author_facet Ng, Curtise
Sun, Zhonghua
author_sort Ng, Curtise
building Curtin Institutional Repository
collection Online Access
description The diagnostic reference levels (DRLs) concept is a methodology proposed by the International Commission on Radiological Protection (ICRP) for identifying any unusual high patient doses involved in radiological examinations. However, some challenges are anticipated in the DRLs concept including resource demand for running the audit cycle by individual imaging departments and availability of DRLs. The objective of this study was to develop an online automatic DRLs management system for digital radiography (DR) with the aim of addressing the challenges of the DRLs obligation. An online automatic DRLs management system for DR composed of freeware was developed. The system was tested with 75 DR images. This pilot experience shows that the system successfully addresses the challenges in the DRLs management, i.e. resource demand for running the audit cycle by individual imaging departments and availability of DRLs. It can provide at a low cost an efficient and effective solution to the implementation of regular audits of patient doses using DR in busy clinical departments. It can also contribute to the development of DRLs at local and national levels. In this way, any unacceptable radiological practice (examination used unjustified high radiation dose) can be identified.
first_indexed 2025-11-14T07:06:42Z
format Journal Article
id curtin-20.500.11937-14141
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:06:42Z
publishDate 2011
publisher Elsevier Ireland Ltd
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-141412019-02-19T05:34:54Z Development of an Online Automatic Diagnostic Reference Levels Management System for Digital Radiography: A Pilot Experience Ng, Curtise Sun, Zhonghua PACS Diagnostic Reference Levels Digital Radiography Radiation Dose Monitoring The diagnostic reference levels (DRLs) concept is a methodology proposed by the International Commission on Radiological Protection (ICRP) for identifying any unusual high patient doses involved in radiological examinations. However, some challenges are anticipated in the DRLs concept including resource demand for running the audit cycle by individual imaging departments and availability of DRLs. The objective of this study was to develop an online automatic DRLs management system for digital radiography (DR) with the aim of addressing the challenges of the DRLs obligation. An online automatic DRLs management system for DR composed of freeware was developed. The system was tested with 75 DR images. This pilot experience shows that the system successfully addresses the challenges in the DRLs management, i.e. resource demand for running the audit cycle by individual imaging departments and availability of DRLs. It can provide at a low cost an efficient and effective solution to the implementation of regular audits of patient doses using DR in busy clinical departments. It can also contribute to the development of DRLs at local and national levels. In this way, any unacceptable radiological practice (examination used unjustified high radiation dose) can be identified. 2011 Journal Article http://hdl.handle.net/20.500.11937/14141 10.1016/j.cmpb.2010.07.008 Elsevier Ireland Ltd fulltext
spellingShingle PACS
Diagnostic Reference Levels
Digital Radiography
Radiation Dose Monitoring
Ng, Curtise
Sun, Zhonghua
Development of an Online Automatic Diagnostic Reference Levels Management System for Digital Radiography: A Pilot Experience
title Development of an Online Automatic Diagnostic Reference Levels Management System for Digital Radiography: A Pilot Experience
title_full Development of an Online Automatic Diagnostic Reference Levels Management System for Digital Radiography: A Pilot Experience
title_fullStr Development of an Online Automatic Diagnostic Reference Levels Management System for Digital Radiography: A Pilot Experience
title_full_unstemmed Development of an Online Automatic Diagnostic Reference Levels Management System for Digital Radiography: A Pilot Experience
title_short Development of an Online Automatic Diagnostic Reference Levels Management System for Digital Radiography: A Pilot Experience
title_sort development of an online automatic diagnostic reference levels management system for digital radiography: a pilot experience
topic PACS
Diagnostic Reference Levels
Digital Radiography
Radiation Dose Monitoring
url http://hdl.handle.net/20.500.11937/14141