Robust control algorithm for grid-interfaced three-phase inverters with high-bandwidth LCL filter

Tall, slender structures and long bridges that inherit numerous uncertainties due to model errors, stress calculations, material properties, and load environments, may undergo large forces from natural hazards such as earthquakes and strong wind events. The paper develops a robust active control app...

Full description

Bibliographic Details
Main Authors: Sagha, H., Ghosh, Arindam, Ledwich, G., Nourbakhsh, G.
Other Authors: -
Format: Conference Paper
Published: - 2013
Online Access:http://hdl.handle.net/20.500.11937/13887
_version_ 1848748468463468544
author Sagha, H.
Ghosh, Arindam
Ledwich, G.
Nourbakhsh, G.
author2 -
author_facet -
Sagha, H.
Ghosh, Arindam
Ledwich, G.
Nourbakhsh, G.
author_sort Sagha, H.
building Curtin Institutional Repository
collection Online Access
description Tall, slender structures and long bridges that inherit numerous uncertainties due to model errors, stress calculations, material properties, and load environments, may undergo large forces from natural hazards such as earthquakes and strong wind events. The paper develops a robust active control approach with parametric uncertainties in the system and control input, and unstructured uncertainties in disturbance input matrices based on an uncertain structural system. Special single valued decomposition (SVD) is applied to structured uncertain structures. The robust control law provides robust relative stability, an H8-norm disturbance attenuation and H2 optimality. The H8 norm of the transfer function from the external disturbance forces (e.g., earthquake, wind, and etc.) to the observed system states is restricted by a prescribed attenuation index d. Preservation of robust H2 optimality of uncertain structural systems is discussed. Considered uncertainties are both structured uncertainties and norm-bounded unstructured uncertainties. Numerical simulations that use the robust controller show significant reduction in vibrations. The resulting approach to robust control may be applied to analysis and design of practical structural systems
first_indexed 2025-11-14T07:05:31Z
format Conference Paper
id curtin-20.500.11937-13887
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:05:31Z
publishDate 2013
publisher -
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-138872017-02-28T01:34:36Z Robust control algorithm for grid-interfaced three-phase inverters with high-bandwidth LCL filter Sagha, H. Ghosh, Arindam Ledwich, G. Nourbakhsh, G. - Tall, slender structures and long bridges that inherit numerous uncertainties due to model errors, stress calculations, material properties, and load environments, may undergo large forces from natural hazards such as earthquakes and strong wind events. The paper develops a robust active control approach with parametric uncertainties in the system and control input, and unstructured uncertainties in disturbance input matrices based on an uncertain structural system. Special single valued decomposition (SVD) is applied to structured uncertain structures. The robust control law provides robust relative stability, an H8-norm disturbance attenuation and H2 optimality. The H8 norm of the transfer function from the external disturbance forces (e.g., earthquake, wind, and etc.) to the observed system states is restricted by a prescribed attenuation index d. Preservation of robust H2 optimality of uncertain structural systems is discussed. Considered uncertainties are both structured uncertainties and norm-bounded unstructured uncertainties. Numerical simulations that use the robust controller show significant reduction in vibrations. The resulting approach to robust control may be applied to analysis and design of practical structural systems 2013 Conference Paper http://hdl.handle.net/20.500.11937/13887 - restricted
spellingShingle Sagha, H.
Ghosh, Arindam
Ledwich, G.
Nourbakhsh, G.
Robust control algorithm for grid-interfaced three-phase inverters with high-bandwidth LCL filter
title Robust control algorithm for grid-interfaced three-phase inverters with high-bandwidth LCL filter
title_full Robust control algorithm for grid-interfaced three-phase inverters with high-bandwidth LCL filter
title_fullStr Robust control algorithm for grid-interfaced three-phase inverters with high-bandwidth LCL filter
title_full_unstemmed Robust control algorithm for grid-interfaced three-phase inverters with high-bandwidth LCL filter
title_short Robust control algorithm for grid-interfaced three-phase inverters with high-bandwidth LCL filter
title_sort robust control algorithm for grid-interfaced three-phase inverters with high-bandwidth lcl filter
url http://hdl.handle.net/20.500.11937/13887