CT virtual intravascular endoscopy in the follow-up of endoluminal fenestrated stent grafts

Purpose: To investigate the potential value of CT virtual intravascular endoscopy in the follow-up of patients with abdominal aortic aneurysms treated with endoluminal fenestrated stent grafts.Methods and Materials: Eight patients with abdominal aortic aneurysms unsuitable for open surgery or conven...

Full description

Bibliographic Details
Main Authors: Zhonghua, Sun, Nadkarni, S., Allen, Yvonne, Green, R., Hartley, D., Lawrence-Brown, Michael
Format: Journal Article
Published: Blackwell Publishing 2007
Subjects:
Online Access:http://hdl.handle.net/20.500.11937/13502
_version_ 1848748364357697536
author Zhonghua, Sun
Nadkarni, S.
Allen, Yvonne
Green, R.
Hartley, D.
Lawrence-Brown, Michael
author_facet Zhonghua, Sun
Nadkarni, S.
Allen, Yvonne
Green, R.
Hartley, D.
Lawrence-Brown, Michael
author_sort Zhonghua, Sun
building Curtin Institutional Repository
collection Online Access
description Purpose: To investigate the potential value of CT virtual intravascular endoscopy in the follow-up of patients with abdominal aortic aneurysms treated with endoluminal fenestrated stent grafts.Methods and Materials: Eight patients with abdominal aortic aneurysms unsuitable for open surgery or conventional endovascular repair undergoing fenestrated stent grafts were included in the study. Both pre-and post-fenestration multislice CT data were collected in these patients and used for generation of virtual intravascular endoscopy images of aortic ostium and endovascular stents. Virtual endoscopy images were compared with conventional axial CT and multiplanar images with the aim of identifying the appearances of the endoluminal stents. The length of endoluminal stents that protruded into the aortic lumen was measured on virtual endoscopy images.Results: Variable fenestrations were deployed in 27 aortic branches with scallop fenestration implanted in 5 aortic ostia, large fenestration in 7 aortic ostia and small fenestration in 15 renal ostia, respectively. All of the fenestrated branches remained patent. Virtual endoscopy was superior to conventional 2D images in the visualization of configuration of endovascular stents. Most of the stents (68%) were found to be circular visualized on virtual endoscopy images, while the remaining stents were irregular in terms of endoluminal appearances. 95% of these stents were shown to protrude into the lumen with length less than 7.0 mm. There is no significant difference of the diameters of aortic ostia between pre-and post- fenestration (p>0.05).Conclusion: Our preliminary study shows that virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with endoluminal fenestrated stent grafts.
first_indexed 2025-11-14T07:03:52Z
format Journal Article
id curtin-20.500.11937-13502
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:03:52Z
publishDate 2007
publisher Blackwell Publishing
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-135022018-10-01T03:26:39Z CT virtual intravascular endoscopy in the follow-up of endoluminal fenestrated stent grafts Zhonghua, Sun Nadkarni, S. Allen, Yvonne Green, R. Hartley, D. Lawrence-Brown, Michael virtual intravascular endoscopy Fenestrated stent graft aortic ostium 3D visualisation Purpose: To investigate the potential value of CT virtual intravascular endoscopy in the follow-up of patients with abdominal aortic aneurysms treated with endoluminal fenestrated stent grafts.Methods and Materials: Eight patients with abdominal aortic aneurysms unsuitable for open surgery or conventional endovascular repair undergoing fenestrated stent grafts were included in the study. Both pre-and post-fenestration multislice CT data were collected in these patients and used for generation of virtual intravascular endoscopy images of aortic ostium and endovascular stents. Virtual endoscopy images were compared with conventional axial CT and multiplanar images with the aim of identifying the appearances of the endoluminal stents. The length of endoluminal stents that protruded into the aortic lumen was measured on virtual endoscopy images.Results: Variable fenestrations were deployed in 27 aortic branches with scallop fenestration implanted in 5 aortic ostia, large fenestration in 7 aortic ostia and small fenestration in 15 renal ostia, respectively. All of the fenestrated branches remained patent. Virtual endoscopy was superior to conventional 2D images in the visualization of configuration of endovascular stents. Most of the stents (68%) were found to be circular visualized on virtual endoscopy images, while the remaining stents were irregular in terms of endoluminal appearances. 95% of these stents were shown to protrude into the lumen with length less than 7.0 mm. There is no significant difference of the diameters of aortic ostia between pre-and post- fenestration (p>0.05).Conclusion: Our preliminary study shows that virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with endoluminal fenestrated stent grafts. 2007 Journal Article http://hdl.handle.net/20.500.11937/13502 10.1111/j.1440-1673.2007.01878.x Blackwell Publishing fulltext
spellingShingle virtual intravascular endoscopy
Fenestrated stent graft
aortic ostium
3D visualisation
Zhonghua, Sun
Nadkarni, S.
Allen, Yvonne
Green, R.
Hartley, D.
Lawrence-Brown, Michael
CT virtual intravascular endoscopy in the follow-up of endoluminal fenestrated stent grafts
title CT virtual intravascular endoscopy in the follow-up of endoluminal fenestrated stent grafts
title_full CT virtual intravascular endoscopy in the follow-up of endoluminal fenestrated stent grafts
title_fullStr CT virtual intravascular endoscopy in the follow-up of endoluminal fenestrated stent grafts
title_full_unstemmed CT virtual intravascular endoscopy in the follow-up of endoluminal fenestrated stent grafts
title_short CT virtual intravascular endoscopy in the follow-up of endoluminal fenestrated stent grafts
title_sort ct virtual intravascular endoscopy in the follow-up of endoluminal fenestrated stent grafts
topic virtual intravascular endoscopy
Fenestrated stent graft
aortic ostium
3D visualisation
url http://hdl.handle.net/20.500.11937/13502