Alternate electrode placement for whole body and segmental bioimpedance spectroscopy

Bioimpedance spectroscopy (BIS) is frequently used to monitor body fluid and body composition in healthy and clinical populations. BIS guidelines state that there should be no skin lesions at the site of electrodes, and if lesions are present, electrode positions should be changed. However, alternat...

Full description

Bibliographic Details
Main Authors: Grisbrook, Tiffany, Kenworthy, P., Phillips, M., Gittings, P., Wood, F., Edgar, D.
Format: Journal Article
Published: 2015
Online Access:http://hdl.handle.net/20.500.11937/12629
_version_ 1848748128976502784
author Grisbrook, Tiffany
Kenworthy, P.
Phillips, M.
Gittings, P.
Wood, F.
Edgar, D.
author_facet Grisbrook, Tiffany
Kenworthy, P.
Phillips, M.
Gittings, P.
Wood, F.
Edgar, D.
author_sort Grisbrook, Tiffany
building Curtin Institutional Repository
collection Online Access
description Bioimpedance spectroscopy (BIS) is frequently used to monitor body fluid and body composition in healthy and clinical populations. BIS guidelines state that there should be no skin lesions at the site of electrodes, and if lesions are present, electrode positions should be changed. However, alternate electrode positions are yet to be reported. This study aimed to determine if ventral electrode placements were suitable alternatives for whole body and segmental BIS measurements. Three alternate electrode placements were assessed for whole body BIS using a combination of ventral hand and foot electrode placements. An alternate position was assessed for upper and lower body segmental BIS. The results demonstrated that for whole body BIS, if drive and sense electrodes on the hand are moved to ventral positions, but foot electrodes remain in standard positions, then whole body BIS variables were comparable to standard electrode positioning (percentage difference range=0.01 to 1.65%, p=0.211–0.937). The alternate electrode placement for upper limb segmental BIS, results in BIS variables that are comparable to that of the standard positioning (percentage difference range=0.24–3.51%, p=0.393–0.604). The alternate lower limb electrode position significantly altered all resistance and predicted BIS variables for whole body and lower limb segmental BIS (percentage difference range=1.06–12.09%, p<0.001). If wounds are present on the hands and/or wrist, then the alternate electrode position described in this study is valid, for whole body and upper limb segmental BIS.
first_indexed 2025-11-14T07:00:08Z
format Journal Article
id curtin-20.500.11937-12629
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T07:00:08Z
publishDate 2015
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-126292017-09-13T14:56:52Z Alternate electrode placement for whole body and segmental bioimpedance spectroscopy Grisbrook, Tiffany Kenworthy, P. Phillips, M. Gittings, P. Wood, F. Edgar, D. Bioimpedance spectroscopy (BIS) is frequently used to monitor body fluid and body composition in healthy and clinical populations. BIS guidelines state that there should be no skin lesions at the site of electrodes, and if lesions are present, electrode positions should be changed. However, alternate electrode positions are yet to be reported. This study aimed to determine if ventral electrode placements were suitable alternatives for whole body and segmental BIS measurements. Three alternate electrode placements were assessed for whole body BIS using a combination of ventral hand and foot electrode placements. An alternate position was assessed for upper and lower body segmental BIS. The results demonstrated that for whole body BIS, if drive and sense electrodes on the hand are moved to ventral positions, but foot electrodes remain in standard positions, then whole body BIS variables were comparable to standard electrode positioning (percentage difference range=0.01 to 1.65%, p=0.211–0.937). The alternate electrode placement for upper limb segmental BIS, results in BIS variables that are comparable to that of the standard positioning (percentage difference range=0.24–3.51%, p=0.393–0.604). The alternate lower limb electrode position significantly altered all resistance and predicted BIS variables for whole body and lower limb segmental BIS (percentage difference range=1.06–12.09%, p<0.001). If wounds are present on the hands and/or wrist, then the alternate electrode position described in this study is valid, for whole body and upper limb segmental BIS. 2015 Journal Article http://hdl.handle.net/20.500.11937/12629 10.1088/0967-3334/36/10/2189 restricted
spellingShingle Grisbrook, Tiffany
Kenworthy, P.
Phillips, M.
Gittings, P.
Wood, F.
Edgar, D.
Alternate electrode placement for whole body and segmental bioimpedance spectroscopy
title Alternate electrode placement for whole body and segmental bioimpedance spectroscopy
title_full Alternate electrode placement for whole body and segmental bioimpedance spectroscopy
title_fullStr Alternate electrode placement for whole body and segmental bioimpedance spectroscopy
title_full_unstemmed Alternate electrode placement for whole body and segmental bioimpedance spectroscopy
title_short Alternate electrode placement for whole body and segmental bioimpedance spectroscopy
title_sort alternate electrode placement for whole body and segmental bioimpedance spectroscopy
url http://hdl.handle.net/20.500.11937/12629