Coking-free direct-methanol-flame fuel cell with traditional nickel-cermet anode

This paper presents a systematic study of a direct-flame solid oxide fuel cell (DF-SOFC) operating on methanol and ethanol flames by SEM, EIS, I-V polarization and mass spectrometer (MS) characterizations and numerical simulation. The experimental study demonstrated that, by adopting a conventional...

Full description

Bibliographic Details
Main Authors: Sun, L., Hao, Y., Zhang, C., Ran, R., Shao, Zongping
Format: Journal Article
Published: Elsevier Ltd 2010
Online Access:http://hdl.handle.net/20.500.11937/12398
Description
Summary:This paper presents a systematic study of a direct-flame solid oxide fuel cell (DF-SOFC) operating on methanol and ethanol flames by SEM, EIS, I-V polarization and mass spectrometer (MS) characterizations and numerical simulation. The experimental study demonstrated that, by adopting a conventional Ni + Sm0.2Ce0.8O1.9 (SDC) anode, irreversible carbon deposition and a drop of cell performance was observed when running the cell on an ethanol flame, while no carbon was deposited by operating on a methanol flame. Fuel cell stability tests indicated significant degradation in performance after 3 h of operation on an ethanol flame, while no degradation was observed after 30 h of operation on a methanol flame. A simple qualitative explanation of the difference observed in the electrochemical performance for the fuel cell operating on a methanol flame and an ethanol flame is presented based on numerical simulation. © 2010 Professor T. Nejat Veziroglu. Published by Elsevier Ltd. All rights reserved.