Electrochemical Immunochip Sensor for Aflatoxin M1 Detection

An investigation into the fabrication, electrochemicalcharacterization, and development of a microelectrodearray (MEA) immunosensor for aflatoxin M1 is presentedin this paper. Gold MEAs (consisting of 35 microsquareelectrodes with 20 µm × 20 µm dimensionsand edge-to-edge spacing of 200 µm) together...

Full description

Bibliographic Details
Main Authors: Parker, C., Lanyon, Y., Manning, M., Arrigan, Damien, Tothill, I.
Format: Journal Article
Published: American Chemical Society 2009
Online Access:http://hdl.handle.net/20.500.11937/10094
_version_ 1848746137615335424
author Parker, C.
Lanyon, Y.
Manning, M.
Arrigan, Damien
Tothill, I.
author_facet Parker, C.
Lanyon, Y.
Manning, M.
Arrigan, Damien
Tothill, I.
author_sort Parker, C.
building Curtin Institutional Repository
collection Online Access
description An investigation into the fabrication, electrochemicalcharacterization, and development of a microelectrodearray (MEA) immunosensor for aflatoxin M1 is presentedin this paper. Gold MEAs (consisting of 35 microsquareelectrodes with 20 µm × 20 µm dimensionsand edge-to-edge spacing of 200 µm) together with onchipreference and counter electrodes were fabricatedusing standard photolithographic methods. The MEAswere then characterized by cyclic voltammetry, and thebehavior of the on-chip electrodes were evaluated. Themicroarray sensors were assessed for their applicabilityto the development of an immunosensor for theanalysis of aflatoxin M1 directly in milk samples.Following the sensor surface silanization, antibodieswere immobilized by cross-linking with 1,4-phenylenediisothiocyanate (PDITC). Surface characterization wasconducted by electrochemistry, fluorescence microscopy,scanning electron microscopy (SEM), and atomicforce microscopy (AFM). A competitive enzyme linkedimmunosorbent assay (ELISA) assay format was developedon the microarray electrode surface using the3,3,5',5'-tetramethylbenzidine dihyrochloride (TMB)/H2O2 electrochemical detection scheme with horseradishperoxidase (HRP) as the enzyme label. The performanceof the assay and the microarray sensor werecharacterized in pure buffer conditions before applyingto the milk samples. With the use of this approach,the detection limit for aflatoxin M1 in milk was estimatedto be 8 ng L-1, with a dynamic detectionrange of 10-100 ng L-1, which meets present legislativelimits of 50 ng L-1. The milk interference with thesensor surface was also found to be minimal. Thesedevices show high potential for development of a rangeof new applications which have previously only beendetected using elaborate instrumentation.
first_indexed 2025-11-14T06:28:28Z
format Journal Article
id curtin-20.500.11937-10094
institution Curtin University Malaysia
institution_category Local University
last_indexed 2025-11-14T06:28:28Z
publishDate 2009
publisher American Chemical Society
recordtype eprints
repository_type Digital Repository
spelling curtin-20.500.11937-100942017-02-28T01:32:00Z Electrochemical Immunochip Sensor for Aflatoxin M1 Detection Parker, C. Lanyon, Y. Manning, M. Arrigan, Damien Tothill, I. An investigation into the fabrication, electrochemicalcharacterization, and development of a microelectrodearray (MEA) immunosensor for aflatoxin M1 is presentedin this paper. Gold MEAs (consisting of 35 microsquareelectrodes with 20 µm × 20 µm dimensionsand edge-to-edge spacing of 200 µm) together with onchipreference and counter electrodes were fabricatedusing standard photolithographic methods. The MEAswere then characterized by cyclic voltammetry, and thebehavior of the on-chip electrodes were evaluated. Themicroarray sensors were assessed for their applicabilityto the development of an immunosensor for theanalysis of aflatoxin M1 directly in milk samples.Following the sensor surface silanization, antibodieswere immobilized by cross-linking with 1,4-phenylenediisothiocyanate (PDITC). Surface characterization wasconducted by electrochemistry, fluorescence microscopy,scanning electron microscopy (SEM), and atomicforce microscopy (AFM). A competitive enzyme linkedimmunosorbent assay (ELISA) assay format was developedon the microarray electrode surface using the3,3,5',5'-tetramethylbenzidine dihyrochloride (TMB)/H2O2 electrochemical detection scheme with horseradishperoxidase (HRP) as the enzyme label. The performanceof the assay and the microarray sensor werecharacterized in pure buffer conditions before applyingto the milk samples. With the use of this approach,the detection limit for aflatoxin M1 in milk was estimatedto be 8 ng L-1, with a dynamic detectionrange of 10-100 ng L-1, which meets present legislativelimits of 50 ng L-1. The milk interference with thesensor surface was also found to be minimal. Thesedevices show high potential for development of a rangeof new applications which have previously only beendetected using elaborate instrumentation. 2009 Journal Article http://hdl.handle.net/20.500.11937/10094 American Chemical Society restricted
spellingShingle Parker, C.
Lanyon, Y.
Manning, M.
Arrigan, Damien
Tothill, I.
Electrochemical Immunochip Sensor for Aflatoxin M1 Detection
title Electrochemical Immunochip Sensor for Aflatoxin M1 Detection
title_full Electrochemical Immunochip Sensor for Aflatoxin M1 Detection
title_fullStr Electrochemical Immunochip Sensor for Aflatoxin M1 Detection
title_full_unstemmed Electrochemical Immunochip Sensor for Aflatoxin M1 Detection
title_short Electrochemical Immunochip Sensor for Aflatoxin M1 Detection
title_sort electrochemical immunochip sensor for aflatoxin m1 detection
url http://hdl.handle.net/20.500.11937/10094